BTK-220 Bresle test kit

Bresle Test Kit

The presence of salts on the substrate can lead to the premature failure of the coating system. Most high performance coating systems require that the substrate be cleaned to a recognized standard before the application of the coating.

Once the bresle patch is applied to the surface to be tested distilled water can be analysed using the conductivity meter before being injected into and then extracted from the bresle patch the required amount of times before being analysed again in the conductivity meter. The difference in the two readings show the conductivity of the water, by multiplying the result by 0.4 the presence of salts expressed in parts per million is shown.

Request a quote



    Contact information

    Kelvinstraat 8
    1704 RS Heerhugowaard
    The Netherlands

    Do you have questions about how we can help your company? Send us an email and we’ll get in touch shortly.

    • Navigate to:
    • Product description
    • Ordering information
    • Specifications
    • Delivery includes & special care
    • More than 50 years of experience
    • Airblast offices in 12 countries

    Product description

    The BTK-220 Bresle Test Kit includes all the necessary equipment for assessing the level of soluble salts on blast cleaned surfaces prior to coating. Inside the Bresle Test Kit is a conductivity gauge used for the assessment of soluble salt ions as chlorides, sulphates and nitrates. The Bresle Test Kit complies with the ISO standards, describing the Bresle Method, that state that the conductivity is mainly directly proportional to the concentration of dissolved salts in the solution.

    Contamination of blast-media

    The Bresle Kit is also suitable to determine the contamination of blast-media. This prevents the dissolved salts in the recycled abrasive contaminating the surface being cleaned.

    Features

    Unique Direct Sampling Procedure (DSP) to ensure high speed and accuracy. Up to 60 times more accurate than other test kits available.

    Application areas

    Marine coatings, protective coatings, pipeline coatings, paint production, surface finishing, powder coating.

    Standards: ISO 8502-6, ISO 8502-9, ISO 11127-6.

    Ordering information

    Part no.Description
    7862200BTK-220 Bresle Test Kit, complete (includes spares as shown below)
    Spares
    7862210Bresle patches (pack of 25)
    7862220Digital conductivity meter (waterproof)
    7862221Cleansing solution 50ml
    7862222Calibration solution 84 μS, 50ml
    7862223Cup 30ml (set of 25)
    7862230Syringe incl. needle 3.0ml
    7862240Deionised water 200ml
    Optional
    7862205Calibration Certificate for BTK-220
    7862212Patches Conformance Certificate for BTK-220
    7862213Bresle area mask magnet
    On request
    Beaker for testing of blast media 100ml

    Specifications

    Conductivity Meter Range0.1 – 20,000 mg/m² (with DSP method)
    Conductivity Meter Resolution0.1 mg/m² (with DSP method)
    Conductivity Meter Accuracy1%
    Patches supplied25
    Temperature range ATC0 – 50 °C
    Normalization temperature25 °C
    Auto off8.5 minutes after last key pressed
    IP classIP67
    Auto calibrationat 84 μS/cm
    Patch area12.50 cm²
    Patch typeLatex membrane

    Standard delivery includes

    • Case
    • Digital conductivity meter
    • 25 bresle patches
    • Distilled water
    • Calibration and cleansing solutions
    • Cups and syringes
    • Pictorial manual

    Special care

    • Always clean the instrument after use and keep the instrument in its case when not in
    • Depending on the frequency of use, a thin film may occur on the probe. Use a clean cotton swap and cleansing solution to remove this.
    • Always keep the instrument in its case when not in
    • We recommend annual